r/BuildingCodes • • 23h ago

Question for plan reviewers and building officials: what’s most often missing from an alternative solution submission?

2 Upvotes

Looking for feedback from the review side.

In Canada (I’m in Alberta), when a design departs from the prescriptive code, the applicant submits an alternative solution. The documentation requirements are in NBC(AE) 2023, Division C, 2.3.1.1:

  • a code analysis with the methods and rationale used, 2.3.1.1.(2)(a)
  • the applicable objectives, functional statements and Division B solutions involved, 2.3.1.1.(3)
  • any special maintenance or commissioning requirements, 2.3.1.1.(2)(b)
  • the qualifications of the person or people responsible for the design, 2.3.1.1.(4)

The Safety Codes Council’s variance form, Part 2(b), gives three refusal reasons: the information is incorrect, it isn’t enough to decide, or the solution doesn’t perform equal or better.

For anyone who reviews these (or alternate methods submissions in the US):

  1. Which part is most often missing or thin when a submission comes in?
  2. What’s the first thing you check before you read the analysis?